Electromagnetic Immunity Test |
||
Test | Standard | |
---|---|---|
Electrostatic Discharge Test CD: 30 kV, AD: 30 kV |
IEC/EN 61000-4-2 | |
Radiated Susceptibility Test 1-30 V/m, 80 MHz - 6 GHz |
IEC/EN 61000-4-3 IEC/EN 61000-4-20 |
|
Electrical Fast Transient/Burst Test 0-4kV |
IEC/EN 61000-4-4 | |
Surge Immunity Test / Telecom Surge Immunity Test 0 - 7 kV |
IEC/EN 61000-4-5 | |
Conducted RF Susceptibility Test 1-10 V, 150 kHz — 80 MHz |
IEC/EN 61000-4-6 | |
Power Frequency Magnetic Field Test 3 A/m - 30 A/m |
IEC/EN 61000-4-8 | |
Pulse Frequency Magnetic Field Test 100 A/m — 1000 A/m |
IEC/EN 61000-4-9 | |
Damp Oscillatory Magnetic Field Test 100 A/m |
IEC/EN 61000-4-10 | |
AC Voltage Dips, Short Interruption & Voltage Variation Test 0-100 % |
IEC/EN 61000-4-11 | |
Ring Wave Test 0-6kV |
IEC/EN 61000-4-12 | |
Harmonics and Inter-harmonics Immunity Tests |
IEC/EN 61000-4-13 | |
Voltage Fluctuation Immunity Test | IEC/EN 61000-4-14 | |
Ripple on d.c. input power port Immunity Test |
IEC/EN 61000-4-17 | |
Slow Damp Oscillatory Test 0 - 2.5kV |
IEC/EN 61000-4-18 | |
Fast Damp Oscillatory Test 0 - 4kV |
IEC/EN 61000-4-18 | |
Phase unbalance, Immunity Test | IEC/EN 61000-4-27 | |
Variation of Power Frequency, Immunity Test |
IEC/EN 61000-4-28 | |
DC Voltage Dips, Short Interruption & Voltage Variation Test 0-100 % |
IEC/EN 61000-4-29 | |
Impulse Voltage Test 0.5 — 12 kV |
IEC/EN 60255-5 |
Electromagnetic Emission Test |
||
Test | Standard | |
---|---|---|
Conducted Emission Test 150 kHz — 30 MHz Radiated Emission Test 30 MHz — 6 GHz |
||
CISPR 11 EMl-Industrial, Scientific & Medical Equipment |
||
CISPR 12 EMI- Automotive Equipment | ||
CISPR 13 EMI- Sound & Television Broadcast Equipment |
||
CISPR 14 EMI- Household Appliances & Electric Tools & Equipments |
||
CISPR 15 EMI- Lighting Equipment | ||
CISPR 22 EMI - Information Technology Equipment | ||
CISPR 25 EMI - Automotive Equipment | ||
CISPR 32 EMI - Multimedia Equipment | ||
Disturbance Power Measurement test 30 MHz-300 MHz |
CISPR 14-1/ EN55014-1 | |
Harmonic Emission Test up to 40" Harmonic |
IEC/EN 61000-3-2, IS 14700 (Part 3/Sec 2) | |
Flicker Emission | IEC/EN 61000-3-3 |
EMI-EMC Testing as per Particular |
||
Product | Standard | |
---|---|---|
Electromagnetic Compatibility (EMC) - Part 6-1: Generic Standards - Immunity for Residential, Commercial and Light-Industrial Environments |
IEC/EN 61000-6-1, IS 14700 (Part 6/Sec 1) |
|
Electromagnetic Compatibility (EMC) - Part 6-2: Generic Standards - Immunity for Industrial Environments |
IEC/EN 61000-6-2, IS 14700 (Part 6/Sec 2) |
|
Electromagnetic Compatibility (EMC) - Part 6-3: Generic Standards - Emission Standard for Residential,Commercial and light-industrial environments |
IEC/EN 61000-6-3, 1S 14700 (Part 6/Sec 3) |
|
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission Standard for Industrial Environments |
IEC/EN 61000-6-4, IS 14700 (Part 6/Sec 4) |
|
Electrical equipment for measurement, Control and Laboratory use — EMC Requirements — Part 1: General Requirements Electrical Equipment for Measurement, Control and Laboratory use |
IEC/EN 61326-1 | |
Medical Electrical Equipment - Part 1-2: General Requirements for Basic Safety and Essential Performance -Collateral Standard: Electromagnetic Disturbances - Requirements and Tests |
IEC/EN 60601-1-2 | |
Measuring Relays and Protection Equipment - Part 26: Electromagnetic Compatibility Requirements |
IEC/EN 60255-26 | |
Uninterruptible Power Systems (UPS) - Part 2: Electromagnetic Compatibility (EMC) Requirements |
IEC/EN 62040-2 | |
Equipment for General Lighting Purposes - EMC Immunity Requirements |
IEC/EN 61547 | |
Information Technology Equipment - Immunity Characteristics - Limits and Methods of Measurement |
CISPR 24/EN55024, IS 15039 |
|
Electromagnetic Compatibility Limits & Methods of Measurements of Radio Disturbance Characteristics |
CISPR 13 | |
Electromagnetic compatibility. Product Family Standard for Audio,Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional use.(Emissions) |
EN 55103-2 | |
Electromagnetic Compatibility and Radio Spectrum Matters (ERM);Telecommunication Network Equipment; Electro Magnetic Compatibility (EMC) Requirements |
EN 300386 | |
Limits and Methods of Measurement of Radio Disturbance Characteristics of Electrical Lighting and Similar Equipment |
CISPR 15/ EN 55015 | |
Electromagnetic compatibility - Requirements for Household Appliances, Electric Tools and Similar Apparatus - Part 1: Emission |
CISPR 14-1/EN 55014-1 | |
Electromagnetic Compatibility - Requirements for Household Appliances, Electric Tools and Similar Apparatus Part 2: Immunity — Product Family Standard |
CISPR 14-2/EN 55014-2 | |
Electromagnetic Compatibility of Multimedia Equipment. Emission Requirements |
CISPR - 32 / EN 55032 |
Click here for Scope of Accreditation and then click on TC-5538
Click here for Testing Charges
Mr. C.M.Patil Assistant Director(Testing lab) E-mail : etl@idemi.org Phone No : 022-24050301/02/03/04 ext 235 Mobile No: 9324350952 | 9372330934 (Lab Mobile)